A riser door, also called a riser access panel, is a fire rated steel door that gives maintenance access to the vertical service shafts in multi-storey residential and commercial buildings, where plumbing, electrical cabling, HVAC ductwork and gas pipework run between floors. It keeps the shaft’s fire compartmentation intact while engineers get routine access floor by floor.
Our riser doors are fire rated from both sides for up to 2 hours (BS EN 1634-1), with smoke tested, airtight and 30dB to 48dB acoustic options. They are made from Zintec steel, powder coated RAL 9010 white, with a 3 point locking system and a picture or beaded frame, in single doors up to 2400 x 900mm and double doors up to 2400 x 1800mm. Every door is made to order and despatched within 3 to 5 working days.
Riser doors are essential for modern building design, providing discreet and secure access to service shafts that contain electrical, plumbing, and HVAC systems. Designed to integrate seamlessly into walls and riser cupboards, they allow essential maintenance access without compromising fire safety, acoustic performance, or the overall finish of a space.
Available in a range of fire-rated, acoustic-rated, and airtight options, riser doors are built to meet the demands of commercial and residential environments where compliance, durability, and aesthetics all matter.
What is a riser cupboard?
A riser is the vertical shaft that carries services up through a building. On each floor it is closed off by a riser cupboard, usually in a corridor or communal area, holding electrical distribution, water pipework, soil stacks, data cabling or ventilation ductwork. Because the shaft runs through every floor, it can carry fire and smoke between compartments, so the riser cupboard door has to give the same fire resistance as the wall it sits in.
Riser doors and dry risers
A dry riser is something different: an empty firefighting main that the fire service charges with water. Its inlet and outlet cabinets are in our dry riser cabinets range, and our dry riser cabinets guide explains the regulations.
Our riser doors are fire tested to BS EN 1634-1 from both sides of the wall, so they keep their rating whichever side the fire starts. Choose 2 hours integrity, or 90 minutes integrity with 60 minutes insulation (EI 90/60) where the face of the door must also stay cooler. The rating a door needs comes from the fire strategy for the building and, in England, the guidance in Approved Document B (fire safety) on GOV.UK.
The 2 hour metal and plasterboard riser doors are ambient smoke control tested to BS EN 1634-3, which limits cold smoke leaking past the door in the early stages of a fire. The 90/60 insulated door is not smoke tested.
Acoustic ratings are tested to BS EN ISO 10140-2:
The acoustic seals in the door and frame do the work. Higher ratings suit flats, hotels and offices where riser cupboards open onto corridors.
Cut the structural opening 7 to 10mm larger than the back of frame size (each datasheet gives the figure), fix through the frame, check it is square, then seal both faces with intumescent acrylic mastic. Suitable wall types include plasterboard clad timber and steel stud partitions, masonry and concrete walls at least 140mm thick, and Knauf Shaftwall, as listed on each datasheet.
The plasterboard riser door is air pressure tested to Class 2 under BS EN 1026, with draught, smoke, air, acoustic and intumescent seals. The metal riser doors have no airtightness rating.
The metal riser doors are made from Zintec steel with a 1.2mm door leaf and a 1.5mm frame, powder coated RAL 9010 white at 30% gloss, with other colours on request. A 3 point locking system comes as standard and other lock options are available on request. They are made for heated interiors such as offices, schools and hotels (corrosion class C1), not for outdoor use.
Single riser doors run from 300 x 300mm up to 2400 x 900mm, and double doors up to 2400 x 1800mm. For any size in between, build a door in our made to measure riser door configurator, or send your door schedule and we will quote to your specification.
Riser doors provide essential access across a wide spectrum of
UK buildings:
We offer a specific range of riser doors that are fire rated, tested to UK and European standards (BS EN 1634-1). These include options with 90-minute integrity / 60-minute insulation and 2-hour integrity ratings. It’s essential to check the specification of each product to ensure it meets your project’s fire safety requirements and legal compliance needs. Non-fire-rated access panels are also available for other applications.
We’re able to manufacture air tight access panels however, at a higher cost. These access panels have been tested in accordance with EN 1634-3:2004 & BS EN 1026:2016.
Yes, we offer specific riser door models that have been acoustically tested (to BS EN ISO 10140-2) and provide certified levels of sound reduction, ranging from 30dB up to 48dB. Check the product specification for the exact acoustic rating if sound insulation is a key requirement for your wall installation.
As standard, most of our access panels come with a tee-key (the plastic access panel opens with a flat headed screwdriver), we do offer different locking options if required. Please contact us or choose these on the product page where available.
The most concealed access panel we have for sale is the plasterboard beaded frame.
Can’t find the size you require on our website? Contact us, we guarantee we can manufacture an access panel to suit your project requirements.
Our website lists standard sizes and our standard finish is RAL 9010 30% Gloss. However, we understand that projects often have unique needs. We also offer bespoke riser doors and custom manufacturing services. Please contact our sales team directly on 01922 313518 or email sales@accesspanelsdirect.net to discuss your specific size, finish, or feature requirements.
Unfortunately we do not manufacture waterproof access panels.
Unfortunately we do not sell Access Panels that can be used on the floor. However, we do sell Floor Access Covers.
We can custom manufacture tiled access panels to suit your project requirements, please contact us for a quotation.
If you order a stocked size online, there is no manufacturing involved and you will receive your access panel within 1 to 2 working days. Made to order products show their own despatch time on the product page.
We offer free next working day delivery to mainland UK on stock access panels if you order before 2:30pm (12pm on Friday). Other products show their delivery time on the product page.
Firstly, sorry your access panel has arrived damaged, this is uncommon. Please contact us immediately with photographic evidence and we will gladly get a replacement to you.
The choice depends on your project requirements:
We offer multiple Access Panel types. Our FlipFix easy installation range are the most popular due to their revolutionary and unique FlipFix mechanism.
The standard colour of our access panels is RAL9010 white however, we can powder coat the access panel in almost any RAL colour required. An alternative option is for us to dust prime the access panel which allows the consumer to paint the panel themselves.
Beaded frames are frames which can be plastered over, whereas picture frames is retrofit and no plastering will be required.
A dual purpose access panel is an access panel that can be installed in both a wall or ceiling. Most of our stock panels are dual purpose however, we don’t recommend installing the plastic access panel in a ceiling.
Plasterboard doors with beaded frames are used when you need to plaster over the door and the frame, so all you will see is the outline of the panel in the wall or ceiling. This looks very neat and tidy.
Picture frames are 20mm to 30mm frames around an access panel and the frame will be visible when installed therefore, you don’t have to worry about how neat the hole is. The beaded frame allows you to plaster over it, so all you see is the white door and no frame.
A riser door is designed to safely conceal vertical service shafts (risers) in a building, housing things like electrical wiring, plumbing, and data cables, while providing secure and easy access for essential maintenance, inspection, and repair work. They also play a crucial role in maintaining fire safety compartmentation and acoustic performance within the wall system.
You’re able to use glue to secure the plastic access panel in place.
The time to install our access panels is dependant on which access panel you’re referring to. Our FlipFix range can take approximately 10-15 minutes, whereas standard access panels can take up to 30-45 minutes.
Structural opening is the size of the hole in your wall / ceiling.
The best example would be if you’re ordering a 600 x 600mm Access Panel, then you will need to make the hole in the wall or ceiling (the structural opening) 605 x 605mm. (5mm larger than the panel size). This varies by product (some need 7mm or 10mm larger, and the meter box needs a smaller hole), so always check the Measuring Guide on the product page.
Enjoy the assurance of top quality with every purchase at Access Panels Direct. Our products, including a wide range of access panels available, offer numerous advantages.