1hr Fire Rated, Airtight, Smoke Tested, 30dB Acoustic Rated Access Panel with Picture Frame
Product Reference: APD.MD.PF.SF-FR60.AT.30dB
Features:
- 1hrs fire rated in a wall, 1hrs fire rated in a ceiling.
- 30dB acoustic rated, Air pressure tested & Smoke tested.
- 25mm wide picture frame surround.
- Supplied with a budget lock as standard, other locking options are available as a bespoke option.
- Powder Coated RAL 9010 30% gloss.
Access Panel Specification
The APD.MD.PF.SF-FR60.AT.30dB (Access Panels Direct, Metal Door, Picture Frame, 60 minutes Fire Rated in a ceiling, 60 minutes Fire Rated in a wall, Airtight, 30dB acoustic rated) Access Panel is a fire rated access panel, featuring a picture frame and metal door. As standard, this panel comes with a budget lock, which is operated by a plastic tee key. This access panel is also airtight, smoke tested and 30dB acoustic rated. Other locking options are available (see locking options). This particular access panel can be used in both a wall and ceiling, therefore making it multipurpose. The panel can be purchased in small access panel sizes and large access panel sizes, alternatively, we can manufacture a panel to your custom bespoke size. Please contact us if this is something you require. Manufactured from 1.2mm Zintec Steel, with a polyester powder coating of matt white RAL 9010 30% gloss. The flush metal door has a concealed continuous hinge. The APD.MD.PF.SF/FR60.AT.30dB is manufactured from Zintec Steel with a 0.9mm thick Door and a 0.9mm Frame. The panels door leaf is hinged by a Fixed Pivot Hinge System.
Fire Rating & Test Information
The Panel is 1 Hour Fire Rated for integrity up to 1200X600mm in a wall application tested in accordance with BSEN 1634-1: 2008 and BSEN 1363-1 1999 & up to 1200x600mm in a ceiling application tested in accordance with BS 476: Part 20: 1987.
The Panel is acoustic rated to 30dB tested in accordance with BS EN ISO 140-3:1995.
This Panel was Air Pressure tested in accordance with EN 1634-3:2004. This Panel is Air Pressure tested with 0.0 m3/h leakage at 10Pa when a negative or positive pressure was applied. When tested at 50Pa there was 0.0 m3/h leakage under positive pressure and 0.1 m3/h leakage under negative pressure.
The Panel is Smoke Tested to 25PA tested in accordance with EN 1634-3:2004.
Types & Dimensions
Please note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 7mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 607 x 607 (See sizes below). Non standard sizes for access panels are available upon request, please contact our sales department.
Sizes | Structural Opening | ||
---|---|---|---|
(x) | (y) | (x) | (y) |
300 | 300 | 307 | 307 |
450 | 450 | 457 | 457 |
550 | 550 | 557 | 557 |
600 | 600 | 607 | 607 |